CGHLV - 822809-FUJI RF-10 X-RAY FIXER & REPLINISHER

Product Identification

Product ID:822809-FUJI RF-10 X-RAY FIXER & REPLINISHER
MSDS Date:06/10/1997
FSC:6850
NIIN:00F054658
MSDS Number: CGHLV

Responsible Party
FUJI HUNT PHOTOGRAPHIC CHEMICALS INC
W 115 CENTURY RD
PARAMUS, NJ 07653-0988
US

Emergency Phone: 800-OLIN-911/800-344-1847

Info Phone: 201-967-9603

Cage: 73843

Contractor
FUJI HUNT PHOTOGRAPHIC CHEMICALS INC
PARAMUS, NJ 07653-0988 US

Telephone: 201-967-9603

Cage: 73843

Ingredients

ACETIC ACID (GLACIAL), ETHANOIC ACID *97-4*

CAS: 64-19-7

RTECS: AF1225000

Fraction By Weight: 1-5%

OSHA PEL 25 MG/CUM

ACGIH TLV: 25 MG/CUM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


AMMONIUM THIOSULFATE

CAS: 7783-18-8

RTECS: XN6465000

Fraction By Weight: 35-40%


SODIUM ACETATE, ANHYDROUS

CAS: 126-96-5

RTECS: AJ4375000

Fraction By Weight: 5-10%


SODIUM BISULFITE

CAS: 7631-90-5

RTECS: VZ2000000

Fraction By Weight: 1-5%

ACGIH TLV: 5 MG/CUM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


SODIUM THIOSULFATE ANHYDROUS; THIOSULFURIC ACID, DISODIUM

CAS: 7772-98-7

RTECS: XN6476000

Fraction By Weight: 1-5%


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 40-45%


SODIUM CHLORATE

CAS: 7775-09-9

RTECS: FO0525000

Hazards

LD50 LC50 Mixture:ORAL LD50(RAT): >5000 MG/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN/EYES: IRRITATION. INHALATION:
IRRITATION TO RESPIRATORY TRACT & MUCOUS MEMBRANES.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, NAUSEA, VOMITING.
Medical Cond Aggravated by Exposure:ALLERGIC REACTION TO SULFITES MAY
CAUSE RESPIRATORY DISTRESS.

First Aid

First Aid:EYES/SKIN: FLUSH W/COOL WATER FOR 15 MINS. INHALATION: REMOVE
TO FRESH AIR. OBTAIN MEDICAL ATTENTION IN ALL CASES.

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE
Extinguishing Media:WATER SPRAY, DRY CHEMICAL, ALCOHOL FOAM/CO2.
Fire Fighting Procedures:USE WATER SPRAY TO COOL CONTAINERS & TO
DISPERSE UN-IGNITED VAPORS. USE NIOSH/MSHA APPROVED POSITIVE
PRESSURE SCBA. REMOVE CONTAINERS SAFELY W/O RISK.
Unusual Fire/Explosion Hazard:MAY PRODUCE HAZARDOUS GASES UNDER FIRE
CONDITIONS. EVACUATE AREA & FIGHT FIRE FROM A SAFE DISTANCE. FIRE
MEDIA RUN-OFF CAN DAMAGE THE ENVIRONMENT.

Accidental Release

Spill Release Procedures:WEAR PERSONAL PROTECTIVE CLOTHING & EQUIPMENT.
RESPIRATORY PROTECTION MAY BE REQUIRED IN CONFINED SPACES WHERE THE
TLV/PEL IS EXCEEDED. STOP THE SOURCE OF LEAK. ISOLATE BY DIKING &
ADD DRY ABSORBENT, CLEAN & PLACE IN AN APPROVED DOT CONTAINER &
SEAL.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE.
USE ONLY W/ADEQUATE VENTILATION. STORE IN A COOL, DRY, WELL
VENTILATED AREA.
Other Precautions:AVOID CONTACT W/EYES, SKIN/CLOTHING. AVOID BREATHING
MIST/VAPOR. DON'T INGEST.

Exposure Controls

Respiratory Protection:IF USED UNDER NORMAL CONDITIONS & W/ADEQUATE
VENTILATION, RESPIRATORY PROTECTION ISN'T REQUIRED. BUT RESPIRATORY
PROTECTION MAY BE REQUIRED IN CASES OF LARGE SPILLS/IN CONFINED
SPACES WHERE TLV/PEL IS EXCEEDED.
Ventilation:LOCAL/MECHANICAL EXHAUST IS RECOMMENDED TO MINIMIZE
EXPOSURE TO MIST & VAPORS/(FUME HOOD).
Protective Gloves:NEOPRENE
Eye Protection:CHEMICAL SAFETY GOGGLES
Other Protective Equipment:APRON.
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE. DISCARD CONTAMINATED LEATHER SHOES. WASH THOROUGHLY AFTER
HANDLING.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:>212F
Melt/Freeze Pt:M.P/F.P Text:NONE
Vapor Pres:17
Spec Gravity:1.33
pH:5.1
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR COLORLESS AQUEOUS LIQUID W/VINEGAR ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS, STRONG ACIDS & STRONG BASES.
Stability Condition to Avoid:EXCESSIVE HEAT.
Hazardous Decomposition Products:OXIDES OF SULFUR, OXIDES OF CARBON,
OXIDES OF NITROGEN, AMMONIA.

Disposal

Waste Disposal Methods:DISPOSE OF CONTAMINATED PRODUCT, EMPTY
CONTAINERS & MATERIALS IAW/FEDERAL, STATE & LOCAL REGULATIONS.
DISCHARGE OF PROCESSING EFFLUENT TO THE SEWER MAY REQUIRE A PERMIT.
DON'T DISCHARGE EFFLUENT SOLUT IONS TO SEPTIC SYSTEMS.

Other Information

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.